EdgeAccess 9145E NID Software Version 4.10User Manual

Strona 2

xChapter 10. CoS Configuration... 183Class of Service ...

Strona 3 - How this Manual is Organized

9145E NID Software User’s Manual DiagnosticsNetwork Performance88PLPM partner NIDs are aware of their partner Manager IP address and MAC address. Any

Strona 4 - Document Feedback

Diagnostics 9145E NID Software User’s ManualNetwork Performance 89ence its ARP Table to determine whether a Test Packet should be forwarded out its Ne

Strona 5 - Contents

9145E NID Software User’s Manual DiagnosticsNetwork Performance90If the Passive NID experiences a Link Loss or Remote Fault on either of its LAG Ports

Strona 6

Diagnostics 9145E NID Software User’s ManualNetwork Performance 91Figure 4-44 PM on the LAG with passive LAG link downIn Figure 4-44, both NIDs are o

Strona 7

9145E NID Software User’s Manual DiagnosticsNetwork Performance92packets from its MPP port, where they are received by the slave NID’s MPP port and fo

Strona 8

Diagnostics 9145E NID Software User’s ManualNetwork Performance 93In Figure 4-47, the slave NID detects that the master NID has failed. The slave NID

Strona 9

9145E NID Software User’s Manual DiagnosticsNetwork Performance94 Figure 4-49 PM on the LAG with master NID bootingIn Figure 4-49, the slave NID dete

Strona 10

Diagnostics 9145E NID Software User’s ManualNetwork Performance 95The Protective Link PM option appears on the Network Performance screen when the PLP

Strona 11

9145E NID Software User’s Manual DiagnosticsNetwork Performance96• Active The Network port is receiving LACP packets with Synchronization = 1 AND Col

Strona 12

Diagnostics 9145E NID Software User’s ManualNetwork Performance 97• The User and Network ports are both configured for SFP 1000M Auto and the MPP port

Strona 13 - Introduction

9145E NID Software User’s Manual xiTypical Configuration Sequence ...

Strona 14 - 1.3 Three Levels of Security

9145E NID Software User’s Manual DiagnosticsThroughput Testing984.7 Throughput TestingThe on demand throughput allows you to measure throughput betwe

Strona 15 - Getting Started

Diagnostics 9145E NID Software User’s ManualThroughput Testing 994.7.1 Test SetupOn the Diagnostics screen (see Figure 4-1), type 7 and press Enter.

Strona 16 - 2.1.2 9145E Set-up

9145E NID Software User’s Manual DiagnosticsThroughput Testing100• ECE (1 bit) ECN-Echo indicates that the TCP peer is ECN capable if the SYN flag is

Strona 17 - 2.3 Login

Diagnostics 9145E NID Software User’s ManualSOAM Based Diagnostics 101Ping, L2 Ping, Loopback, OAM Loopback) is in progress. If there are no configur

Strona 18 - 2.4 Main Menu

9145E NID Software User’s Manual DiagnosticsSOAM Based Diagnostics102Figure 4-53 Delay Measurement Request screen1. To enter the source MEP ID used t

Strona 19 - Main Menu

Diagnostics 9145E NID Software User’s ManualSOAM Based Diagnostics 103Figure 4-54 Delay Measurement Monitoring screenFigure 4-55 Frame Loss Measurem

Strona 20 - 2.5 Supported MIBs

9145E NID Software User’s Manual DiagnosticsSOAM Based Diagnostics104Figure 4-56 SLM Monitoring screen Canoga Perkins Corp. Ethernet Network

Strona 21 - System Configuration

Diagnostics 9145E NID Software User’s ManualService Activation Testing 1054.9 Service Activation TestingService Activation Testing (SAT) is an out-of

Strona 22 - System Configuration Menu

9145E NID Software User’s Manual DiagnosticsService Activation Testing106The Service Provider must set up a SAT Profile to begin. The Service Provide

Strona 23

Diagnostics 9145E NID Software User’s ManualService Activation Testing 107Figure 4-59 SA System Configuration screen2. To enable SA reflector, type

Strona 24 - IP/SNMP Agent Configuration

9145E NID Software User’s ManualxiiPolicers...

Strona 25

9145E NID Software User’s Manual DiagnosticsService Activation Testing108Figure 4-60 SA Sessions screenFigure 4-61 Frame Length Size screen Canoga P

Strona 26

Diagnostics 9145E NID Software User’s ManualService Activation Testing 1094.9.2 Adding, Deleting or Modifying Service Activation ProfilesTo add, dele

Strona 27

9145E NID Software User’s Manual DiagnosticsService Activation Testing110 Figure 4-63 Create New SA Profile screenChanging the CBS traffic test prior

Strona 28

Diagnostics 9145E NID Software User’s ManualService Activation Testing 11113. Frame Size Mix Indicates frame sizes to be sent during information rate

Strona 29 - 3.2.3 Host Table

9145E NID Software User’s Manual DiagnosticsService Activation Testing112 Figure 4-64 Modify SA Profile screen3. Type the number of the field you wis

Strona 30

Diagnostics 9145E NID Software User’s ManualService Activation Testing 113Figure 4-65 L2 Frame Format screenFigure 4-66 L3 Frame Format screen7. To

Strona 31 - 3.2.4 Trap Table

9145E NID Software User’s Manual DiagnosticsService Activation Testing1148. Frame delay acceptance criteria are expressed in buckets, which may be imp

Strona 32

Diagnostics 9145E NID Software User’s ManualService Activation Testing 115Figure 4-68 Frame Delay Variation Acceptance Criteria screenNOTE: If the pr

Strona 33

9145E NID Software User’s Manual DiagnosticsService Activation Testing116 Figure 4-69 SA Class of Service to PCP equivalency map screen12. Type the n

Strona 34

Diagnostics 9145E NID Software User’s ManualService Activation Testing 1174.9.3 Service Activation TestsTo add, delete, or modify Service Activation

Strona 35

Introduction 9145E NID Software User’s ManualManagement Access1Chapter 1Introduction1.0 About the 9145E SoftwareBuilding on the industry-leading 10/1

Strona 36 - 3.3 Trap Configuration

9145E NID Software User’s Manual DiagnosticsService Activation Testing118SAT, then SAT will run using limited port speed. For example, if the port spe

Strona 37

Diagnostics 9145E NID Software User’s ManualService Activation Testing 1196. To view a Frame Delivery Test report, type 2 and press Enter. The Frame

Strona 38 - 3.4 Security Configuration

9145E NID Software User’s Manual DiagnosticsService Activation Testing120Figure 4-76 L2CP Processing Test screen (2)NOTE: Link OAM PDU, Pause, E-LMI

Strona 39 - Security Configuration

Diagnostics 9145E NID Software User’s ManualService Activation Testing 1218. To view a CIR test report, type 4 and press Enter. The CIR Test Report s

Strona 40

9145E NID Software User’s Manual DiagnosticsService Activation Testing122Figure 4-78 Detailed CIR Test Report screen 10. Type D and press Enter to vi

Strona 41 - 3.5 Account Configuration

Diagnostics 9145E NID Software User’s ManualService Activation Testing 12312. To view Policing Test details, on the Service Activation Test Details sc

Strona 42 - 3.5.2 Add or Edit an Account

9145E NID Software User’s Manual DiagnosticsService Activation Testing12414. To view a CBS test report, on the Service Activation Test Details screen

Strona 43 - Account Configuration

Diagnostics 9145E NID Software User’s ManualService Activation Testing 1254.9.4 L2CP ProfilesTo add, delete, edit and view L2CP profiles, on the Se

Strona 44 - 3.5.3 Delete an Account

9145E NID Software User’s Manual DiagnosticsService Activation Testing12618. To create an L2CP profile, on the L2CP Profiles List screen (Figure 4-59

Strona 45 - 3.6 System Information

Diagnostics 9145E NID Software User’s ManualService Activation Testing 127Figure 4-87 Modify L2CP Profile screen Canoga Perkins Corp. Etherne

Strona 46 - 3.7 RADIUS Client

9145E NID Software User’s Manual IntroductionThree Levels of Security2Secure Shell version 2 (SSH-2) SSH-2 provides authentication and encryption for

Strona 47 - RADIUS Client

9145E NID Software User’s Manual DiagnosticsService Activation Testing128

Strona 48 - SNTP Client Configuration

Port Information 9145E NID Software User’s Manual129Chapter 5Port Information5.0 Port DescriptionThe Port Information screen (Figure 5-1) provides a

Strona 49

9145E NID Software User’s Manual Port InformationLink Status1305.1 Link Status Link Status informs you of the current link status of the User, Networ

Strona 50 - SYSLOG Client Configuration

Port Information 9145E NID Software User’s ManualPort Configuration 1315.2 Port ConfigurationUse the Port Configuration functions to obtain hardware

Strona 51 - 3.10 Hardware Information

9145E NID Software User’s Manual Port InformationPort Configuration1325.2.1 Hardware Information The Hardware Information screen (Figure 5-4) provide

Strona 52 - Hardware Information

Port Information 9145E NID Software User’s ManualPort Configuration 1335.2.2 Functional ConfigurationFrom the Port Configuration screen, select the F

Strona 53 - Diagnostics

9145E NID Software User’s Manual Port InformationPort Configuration134or Disabled. If SFP is selected as the connector, the speed setting is defined

Strona 54 - 4.2 Latency/Jitter Test

Port Information 9145E NID Software User’s ManualPort Configuration 1355.2.3 VLAN ConfigurationFrom the Port Configuration screen, select VLAN Config

Strona 55 - Latency/Jitter Test

9145E NID Software User’s Manual Port InformationPort Configuration1363. Drop Packets with VLAN Tag not matching VLAN Tag A? The 9145E discards all S

Strona 56

Port Information 9145E NID Software User’s ManualPort Configuration 1375.2.3.2 Port VLAN ID Translation TableThe 9145E has the ability to translate cu

Strona 57 - 4.3 PING Generation

Getting Started 9145E NID Software User’s Manual3Chapter 2Getting Started2.0 Configuring Terminal ManagementWhen you use the RS-232 Serial Port for V

Strona 58 - PING Generation

9145E NID Software User’s Manual Port InformationPort Configuration138Figure 5-9 Network Port VLAN ID Translation Table Canoga Perkins Corp.

Strona 59 - 4.4 VLAN Loopback

Port Information 9145E NID Software User’s ManualPort Configuration 1395.2.3.3 P-Bit Translation TableThe 9145E can change the P-Bit setting in VLAN I

Strona 60 - Figure 4-6 VLAN Loopback

9145E NID Software User’s Manual Port InformationPort Configuration1405.2.3.4 C-VLAN/PCP PolicersFor detailed information about policing, see “Policer

Strona 61 - VLAN Loopback

Port Information 9145E NID Software User’s ManualPort Configuration 141 Figure 5-12 Add CE-VLAN screen6. To modify a policer, type A and press Enter.

Strona 62 - 4.4.2 L2 Ping Generation

9145E NID Software User’s Manual Port InformationPort Configuration1425.2.4 Port FiltersPort Filters enables you to discard predefined service frames

Strona 63 - 4.5 Cable Diagnostics

Port Information 9145E NID Software User’s ManualPort Configuration 143ing, the service frame at each egress UNI must be identical to the correspondin

Strona 64 - Cable Diagnostics

9145E NID Software User’s Manual Port InformationPort Configuration144If the 9145E receives a frame with a MAC Destination Address of 01-80-C2-00-00-0

Strona 65 - 4.6 Network Performance

Port Information 9145E NID Software User’s ManualPort Configuration 145Figure 5-14 Port Filters screenTo set the port filters, type the filter item n

Strona 66

9145E NID Software User’s Manual Port InformationPort Configuration1465.2.4.5 L2CP Port FiltersTo enable or disable port filters, on the Port Filters

Strona 67 - 4.6.1.2 One-Way Jitter

Port Information 9145E NID Software User’s ManualPort Configuration 1472. Pause Filter When this attribute is enabled, the 9145E filters all Pause fr

Strona 68

9145E NID Software User’s Manual Getting StartedSetting Up SNMP Network Management42.1 Setting Up SNMP Network ManagementThe 9145E communicates with

Strona 69 - 4.6.2 Profiles

9145E NID Software User’s Manual Port InformationPort Configuration1485.2.5 Port Based VLAN ControlThe Port Based VLAN Control screen (Figure 5-16) i

Strona 70 - 4.6.2.1 Setting up a profile

Port Information 9145E NID Software User’s ManualPort Configuration 1495. Delete Range Removes a range of VLAN IDs from the screen list. Enter the gr

Strona 71

9145E NID Software User’s Manual Port InformationPort Configuration150Figure 5-18 Modify Port Policing Attributes screen Canoga Perkins Corp.

Strona 72

Port Information 9145E NID Software User’s ManualLayer 2 Statistics 1515.3 Layer 2 StatisticsTo view Layer 2 statistics, select Layer 2 Statistics (3

Strona 73

9145E NID Software User’s Manual Port InformationLayer 2 Statistics152Frames Sent The total number of frames sent from the interface since the last re

Strona 74

Port Information 9145E NID Software User’s ManualLayer 2 Statistics 153CRC Errors Number of frames received on the interface that had a length (exclu

Strona 75

9145E NID Software User’s Manual Port InformationLayer 2 Statistics154Tx Multicasts Number of multicast frames transmitted by the interface.VLAN Tagg

Strona 76

Port Information 9145E NID Software User’s ManualRMON Group 1 Statistics 1555.4 RMON Group 1 StatisticsTo view Remote Monitoring Specification (RMON)

Strona 77 - 4.6.3 Test Addresses

9145E NID Software User’s Manual Port InformationRMON Group 1 Statistics156Pkts 65-127 Reports the total number of packets (including bad packets) rec

Strona 78

System Alarms & Logs 9145E NID Software User’s Manual 157Chapter 6System Alarms & Logs6.0 System AlarmsUse the System Alarms screen to view a

Strona 79

Getting Started 9145E NID Software User’s ManualLogin 5Figure 2-1 Screen Format2.3 LoginThe first screen is the Login Screen (Figure 2-2). Type your

Strona 80

9145E NID Software User’s Manual System Alarms & LogsSystem Log1586.1 System LogThe System Log lists all events that occurred since the last powe

Strona 81

System Alarms & Logs 9145E NID Software User’s ManualSystem Log 1596.1.1 Log Display Filter ConfigurationThe 9145E has a flexible System Log Dis

Strona 82 - 4.6.5 Trap Configuration

9145E NID Software User’s Manual System Alarms & LogsSystem Log160

Strona 83 - 4.6.6 Statistics

Utilities 9145E NID Software User’s ManualSet Date and Time161Chapter 7Utilities7.0 Utilities MenuUse the Utilities screen to setup and display basic

Strona 84 - 4.6.7 PM Scheduler

9145E NID Software User’s Manual UtilitiesReset Configuration To Default1627.2 Reset Configuration To DefaultTo reset the configuration to the defaul

Strona 85 - 4.6.8 PM Test Results

Utilities 9145E NID Software User’s ManualPING Generation 1637.5 PING GenerationFrom the Utilities screen, type 5 and press Enter. The PING Generatio

Strona 86

9145E NID Software User’s Manual UtilitiesDynamic ARP Table164From the Utilities screen, type 7 and press Enter. The Static ARP Table screen (Figure 7

Strona 87

Utilities 9145E NID Software User’s ManualLicense Manager 1654. To delete all the addresses, type A and press Enter. You are asked to confirm that you

Strona 88

9145E NID Software User’s Manual UtilitiesLicense Manager1665. Press Esc to return to the Utilities screen. Figure 7-6 License Manager screen NOTE:

Strona 89 - 4.6.9 PM Manual Test

Software Upgrade 9145E NID Software User’s ManualSoftware Reset 167Chapter 8Software Upgrade8.0 Flash MemoryCAUTION: Swap Bank and Software Reset or

Strona 90

9145E NID Software User’s Manual Getting StartedMain Menu6Figure 2-2 Login screenWhen you successfully log in, the Main Menu (Figure 2-3) opens. Use

Strona 91

9145E NID Software User’s Manual Software UpgradeSwap Bank After Download and Reset168To swap banks and reset the 9145E, type 2 and press Enter. Swap

Strona 92

Software Upgrade 9145E NID Software User’s ManualGet Software Upgrades with TFTP 1698.4 Get Software Upgrades with TFTPSoftware can be downloaded fro

Strona 93 - 4.6.11 SAM Test Results

9145E NID Software User’s Manual Software UpgradeHardware Reset1708.5 Hardware ResetTo reset hardware, on the Software Upgrade screen (Figure 8-1), t

Strona 94

Software Upgrade 9145E NID Software User’s ManualSoftware Upgrades Using FTP or SFTP 171Where directory name is the name of the directory where the so

Strona 95 - 4.6.12 SAM Scheduler

9145E NID Software User’s Manual Software UpgradeSoftware Upgrades Using FTP or SFTP172

Strona 96 - 4.6.13 SAM Results Log

Link OAM 9145E NID Software User’s Manual 173Chapter 9Link OAM9.0 Operation, Administration and MaintenanceThe Operation, Administration, and Mainten

Strona 97

9145E NID Software User’s Manual Link OAMOAM Control1749.1 OAM ControlFrom the Link OAM screen, select OAM Control (1) and press Enter. The OAM Contr

Strona 98

Link OAM 9145E NID Software User’s ManualOAM Control 175Link Fault If the link has detected a fault and is transmitting OAMPDUs with a link fault indi

Strona 99 - 4.6.15.1 PLPM Configuration

9145E NID Software User’s Manual Link OAMOAM Control1769.1.7 OAM Admin State This setting enables or disables OAM in the 9145E. 9.1.8 OAM Mode Two m

Strona 100 - Network Performance

Link OAM 9145E NID Software User’s ManualOAM Peer Information 1779.2 OAM Peer InformationThis table contains information about the OAM peer for a par

Strona 101 - 4.6.15.3 How PLPM Works

Getting Started 9145E NID Software User’s ManualMain Menu 76. Utilities The Utilities screen is used to set-up and display basic functional informati

Strona 102

9145E NID Software User’s Manual Link OAMOAM Statistics1789.3 OAM StatisticsThe OAM Statistics screen provides information concerning OAMPDUs, Event

Strona 103

Link OAM 9145E NID Software User’s ManualOAM Event Configuration 1799.4 OAM Event ConfigurationTo configure errors in the OAM, from the Link OAM scre

Strona 104

9145E NID Software User’s Manual Link OAMOAM Event Log1809.5 OAM Event LogThe OAM Event Log Brief Display screen (Figure 9-6) displays only OAM entri

Strona 105

Link OAM 9145E NID Software User’s ManualOAM Event Log 1819.5.1 Event Log Detail Display On the OAM Event Log Brief Display screen (Figure 9-6), type

Strona 106

9145E NID Software User’s Manual Link OAMOAM Event Log182Figure 9-8 Display Filter Configuration screen Canoga Perkins Corp. Ethernet Network

Strona 107

CoS Configuration 9145E NID Software User’s Manual9145E Queuing Functionality 183Chapter 10CoS Configuration10.0 Class of ServiceCAUTION: When CoS Su

Strona 108 - 4.6.15.5 Configuring PLMP

9145E NID Software User’s Manual CoS ConfigurationCoS Support184Figure 10-1 CoS Functional ModelThe 9145E has a set of egress queues assigned to the

Strona 109

CoS Configuration 9145E NID Software User’s ManualClassifier Mapping 185NOTE: The instructions in the following paragraphs pertain to both the Ingress

Strona 110 - 4.7 Throughput Testing

9145E NID Software User’s Manual CoS ConfigurationClassifier Mapping186Type the number of the PCP, or a series of numbers such as 3-7 if desired, and

Strona 111 - 4.7.1 Test Setup

CoS Configuration 9145E NID Software User’s ManualClassifier Mapping 187Figure 10-5 Ingress Untagged Packet Classifier Mapping screen - IP Precedence

Strona 112 - Throughput Testing

NOTICECanoga Perkins has prepared this user’s manual for use by customers and Canoga Perkins personnel as a guide for the proper installation, operati

Strona 113 - 4.8 SOAM Based Diagnostics

9145E NID Software User’s Manual Getting StartedSupported MIBs82.5 Supported MIBsThis section lists all supported MIBs including Standard MIBs and th

Strona 114 - SOAM Based Diagnostics

9145E NID Software User’s Manual CoS ConfigurationClassifier Mapping188Figure 10-6 Ingress Untagged Packet Classifier Mapping screen - DSCP Mode10.3.

Strona 115

CoS Configuration 9145E NID Software User’s ManualQueue Configuration 189press Enter. If a series of codes was chosen, all of those CoSQs will be chan

Strona 116

9145E NID Software User’s Manual CoS ConfigurationQueue Configuration190Figure 10-8 Ingress Queue Configuration screen Canoga Perkins Corp. E

Strona 117 - Service Activation Testing

CoS Configuration 9145E NID Software User’s ManualQueue Configuration 191Figure 10-9 Egress Queue Configuration screen10.4.1 Enable/Disable a QueueT

Strona 118

9145E NID Software User’s Manual CoS ConfigurationEarly Detect Drop Profile Configuration192Type the appropriate number to change the queue size. Pres

Strona 119

CoS Configuration 9145E NID Software User’s ManualEarly Detect Drop Profile Configuration 1935. Type 4, 8 or 12 to view the Match Criteria for the app

Strona 120

9145E NID Software User’s Manual CoS ConfigurationQueue Statistics194Figure 10-11 Egress Match Criteria screen10.6 Queue StatisticsFrom the Class of

Strona 121

CoS Configuration 9145E NID Software User’s ManualQueue Statistics 195Figure 10-12 Queue Statistics screen Canoga Perkins Corp. Ethernet Netw

Strona 122

9145E NID Software User’s Manual CoS ConfigurationQueue Statistics196

Strona 123

Service OAM 9145E NID Software User’s ManualService OAM197Chapter 11Service OAM11.0 Introduction Service OAM (SOAM) allows you to detect, isolate, an

Strona 124

System Configuration 9145E NID Software User’s ManualSystem Configuration Menu9Chapter 3System Configuration3.1 System Configuration MenuThe System C

Strona 125

9145E NID Software User’s Manual Service OAMService OAM19811.1.1 SOAM EntitiesIn order to execute the Service OAM procedures, specific entities must

Strona 126

Service OAM 9145E NID Software User’s ManualService OAM 199Figure 11-1 Positioning of UP/DOWN MEPs11.1.2 Optional SOAM ConfigurationOptionally, SOAM

Strona 127

9145E NID Software User’s Manual Service OAMService OAM200If All-to-One Bundling for SOAM is enabled, and the Network port is S-Tagged, then:• Frames

Strona 128

Service OAM 9145E NID Software User’s ManualService OAM 20111.1.4 SOAM ProtocolsSOAM Connectivity Fault Management provides the following protocols:•

Strona 129

9145E NID Software User’s Manual Service OAMService OAM202Table 11-1. SOAM protocol support for 802.1ag and Y.1731 11.1.5 Typical Service OAM Deploym

Strona 130

Service OAM 9145E NID Software User’s ManualService OAM 203Figure 11-3 Typical Service OAM deployment and applications11.1.6 Typical Configuration S

Strona 131

9145E NID Software User’s Manual Service OAMService OAM2043. Configure the MEPs. Each MEP is associated with an existing MA or MEG, created in step 2.

Strona 132

Service OAM 9145E NID Software User’s ManualSOAM Configuration 205.Figure 11-4 SOAM menu hierarchy11.2 SOAM ConfigurationUse the following steps to

Strona 133

9145E NID Software User’s Manual Service OAMSOAM Configuration206Figure 11-5 Main Menu Figure 11-6 Service OAM Main Menu Canoga Perkins Corp.

Strona 134

Service OAM 9145E NID Software User’s ManualSOAM Configuration 207 Figure 11-7 SOAM Configuration screenNOTE: You can perform system-level configura

Strona 135

9145E NID Software User’s Manual System ConfigurationSystem Configuration Menu10Figure 3-2 Logical Model for a NIDThe forwarding plane is responsible

Strona 136

9145E NID Software User’s Manual Service OAMSOAM Configuration208Figure 11-8 SOAM System Level Configuration screen8. If you chose Locally Assigned i

Strona 137 - 4.9.4 L2CP Profiles

Service OAM 9145E NID Software User’s ManualMaintenance Domains 20911.2.1 SOAM Configuration Error ListThe Configuration Error List is a list of brid

Strona 138

9145E NID Software User’s Manual Service OAMMaintenance Domains210become a point of connectivity to a service instance. Up to eight MDs can be configu

Strona 139

Service OAM 9145E NID Software User’s ManualMaintenance Domains 211• Chassis: the Chassis ID Length, Chassis ID Subtype, and Chassis ID fields of

Strona 140

9145E NID Software User’s Manual Service OAMMaintenance Domains21211.3.3 Delete a Maintenance DomainWhen you delete a Maintenance Domain, all MAs and

Strona 141 - Port Information

Service OAM 9145E NID Software User’s ManualMaintenance Associations 21311.4 Maintenance Associations Maintenance Associations (MAs) are applicable t

Strona 142 - 5.1 Link Status

9145E NID Software User’s Manual Service OAMMaintenance Associations214• S-Tag specifies the single S-Tagged UP MEP configured for the All-to-One Bund

Strona 143 - 5.2 Port Configuration

Service OAM 9145E NID Software User’s ManualMaintenance Associations 21511.4.3 Delete a Maintenance AssociationWhen you delete a Maintenance Associat

Strona 144 - 5.2.1 Hardware Information

9145E NID Software User’s Manual Service OAMMaintenance Associations216b. To remove a peer MEP, type 2 and press Enter. You are prompted for the MEP I

Strona 145 - Port Configuration

Service OAM 9145E NID Software User’s ManualMaintenance Entity Groups 217Figure 11-16 Maintenance Association Peer MEPs screen11.5 Maintenance Entit

Strona 146

System Configuration 9145E NID Software User’s ManualSystem Configuration Menu 11Figure 3-3 Typical Application of the Control Plane EntitiesFigure 3

Strona 147 - 5.2.3 VLAN Configuration

9145E NID Software User’s Manual Service OAMMaintenance Entity Groups21811.5.1 Display Maintenance Entity GroupsTo display a list of existing Mainten

Strona 148

Service OAM 9145E NID Software User’s ManualMaintenance Entity Groups 219• S-Tag specifies the single S-Tagged UP MEP configured for the All-to-One tu

Strona 149

9145E NID Software User’s Manual Service OAMMaintenance Entity Groups220The Canoga Perkins 9145E NID does, however, provide a configuration method tha

Strona 150

Service OAM 9145E NID Software User’s ManualMaintenance Entity Groups 22111.6.7 Delete a Maintenance Entity GroupWhen you delete a Maintenance Entity

Strona 151

9145E NID Software User’s Manual Service OAMMaintenance Entity Groups222• To remove a peer MEP, type 2 and press Enter. You are prompted for the MEP I

Strona 152 - 5.2.3.4 C-VLAN/PCP Policers

Service OAM 9145E NID Software User’s ManualMaintenance End Points 22311.6 Maintenance End PointsA Maintenance Association End Point (MEP) is an acti

Strona 153

9145E NID Software User’s Manual Service OAMMaintenance End Points2247. In the Port field, select User or Network. 8. To accept the new Maintenance En

Strona 154 - 5.2.4 Port Filters

Service OAM 9145E NID Software User’s ManualMaintenance End Points 22511.6.3 Delete a Maintenance End PointWhen you delete a Y.1731 Maintenance End P

Strona 155

9145E NID Software User’s Manual Service OAMMaintenance End Points226• Next Loopback trans. ID The transaction ID that will be used in the next Loo

Strona 156 - 5.2.4.4 Setting Port Filters

Service OAM 9145E NID Software User’s ManualMaintenance End Points 227Figure 11-23 Maintenance End Point Attributes screen (Y.1731)11.6.5 View the C

Strona 157

9145E NID Software User’s Manual System ConfigurationIP/SNMP Agent Configuration12messages. If there is no reply from the CE, the Service Provider wi

Strona 158 - 5.2.4.5 L2CP Port Filters

9145E NID Software User’s Manual Service OAMMaintenance End Points228• On the Maintenance End Point List screen (Figure 11-19), type B and press Enter

Strona 159

Service OAM 9145E NID Software User’s ManualMaintenance End Points 229Press Esc to return to the Maintenance End Point List screen.Figure 11-25 CCM C

Strona 160

9145E NID Software User’s Manual Service OAMMaintenance End Points2304. To set the Initial TTL (time to live) value for the LTM, type 3 and press Ente

Strona 161 - 5.2.6 Port Level Policers

Service OAM 9145E NID Software User’s ManualMaintenance End Points 231Figure 11-27 Linktrace Monitoring screenFigure 11-28 Linktrace Report screen

Strona 162

9145E NID Software User’s Manual Service OAMMaintenance End Points23211.6.7 Loopback ProceduresA loopback request is initiated by a MEP to verify the

Strona 163 - 5.3 Layer 2 Statistics

Service OAM 9145E NID Software User’s ManualMaintenance End Points 2338. To change the Data TLV size, type 7 and press Enter. This value indicates the

Strona 164 - Layer 2 Statistics

9145E NID Software User’s Manual Service OAMMaintenance End Points234Figure 11-30 Sweep Loopback Monitoring screenFigure 11-31 Multicast Loopback Mo

Strona 165

Service OAM 9145E NID Software User’s ManualMaintenance End Points 235 Figure 11-32 Loopback Request screen (unicast regular)11.6.6.2 Monitoring a Lo

Strona 166

9145E NID Software User’s Manual Service OAMMaintenance Intermediate Points23611.7 Maintenance Intermediate PointsMaintenance Intermediate Points (MI

Strona 167 - 5.4 RMON Group 1 Statistics

Service OAM 9145E NID Software User’s ManualMaintenance Intermediate Points 2377. To accept the new Maintenance Intermediate Point settings, type A an

Strona 168 - RMON Group 1 Statistics

System Configuration 9145E NID Software User’s ManualIP/SNMP Agent Configuration 134. Manager C-, T-, or S- VLAN ID When Manager VLAN Tagging is Enab

Strona 169 - System Alarms & Logs

9145E NID Software User’s Manual Service OAMMaintenance Intermediate Points238Figure 11-35 Create a New Maintenance Intermediate Point screen (Y.1731

Strona 170 - 6.1 System Log

Service OAM 9145E NID Software User’s ManualMaintenance Intermediate Points 239 If you are configuring a Y.1731 MIP, go to step 7.Figure 11-36 Mainte

Strona 171 - System Log

9145E NID Software User’s Manual Service OAMConfigure and View SOAM Statistics240Figure 11-37 Maintenance Intermediate Point Attributes screen (Y.173

Strona 172

Service OAM 9145E NID Software User’s ManualConfigure and View SOAM Statistics 241Figure 11-38 SOAM Statistics screenFigure 11-39 SOAM Statistics sc

Strona 173 - Utilities

9145E NID Software User’s Manual Service OAMConfigure and View SOAM Statistics24211.8.1 MEP Statistics1. To display statistics for all MEPs, type 1 a

Strona 174 - 7.4 VT100 Baud Rate

Service OAM 9145E NID Software User’s ManualConfigure and View SOAM Statistics 243Figure 11-41 Maintenance End Point Statistics screen11.8.2 MIP Sta

Strona 175 - 7.6 Static ARP Table

9145E NID Software User’s Manual Service OAMConfigure and View SOAM Statistics244 Figure 11-42 Maintenance Intermediate Point Statistics screenFigure

Strona 176 - 7.7 Dynamic ARP Table

Service OAM 9145E NID Software User’s ManualConfigure and View SOAM Statistics 24511.8.3 Statistics Display ConfirmationThe 9145E NID allows you to m

Strona 177 - 7.8 License Manager

9145E NID Software User’s Manual Service OAMAIS Configuration246Figure 11-45 MIP Summary Statistics Configuration screen11.7 AIS ConfigurationNOTE:

Strona 178 - License Manager

Service OAM 9145E NID Software User’s ManualAIS Configuration 247• Type the MEG ID and press Enter. You are prompted to enter a MEP client MEP ID.• En

Strona 179 - Software Upgrade

9145E NID Software User’s Manual System ConfigurationIP/SNMP Agent Configuration148. Reply to Broadcast Ping Enables or disable the 9145E to reply to

Strona 180

9145E NID Software User’s Manual Service OAMAIS Configuration248Figure 11-47 AIS Server Configuration screen Canoga Perkins Corp. Ethernet N

Strona 181

Configuring EVC 9145E NID Software User’s ManualEVC Functionality249Chapter 12Configuring EVC 12.0 Introduction The 9145E supports VLAN multiplexing

Strona 182 - 8.5 Hardware Reset

9145E NID Software User’s Manual Configuring EVCEVC Functionality250• An EVC record can contain only C-VLANs from a single User Port. EVC records do n

Strona 183

Configuring EVC 9145E NID Software User’s ManualEVC Functionality 251• Number of transmitted frames and bytes on the Network Port• Number of received

Strona 184

9145E NID Software User’s Manual Configuring EVCEVC Functionality252Figure 12-1 EVC menu hierarchy EVC Configuration MenuEVC Record ListCreat

Strona 185 - Link OAM

Configuring EVC 9145E NID Software User’s ManualEVC Configuration 25312.2 EVC ConfigurationNOTE: EVC Configuration Records options replace the VLAN

Strona 186 - 9.1 OAM Control

9145E NID Software User’s Manual Configuring EVCEVC Configuration25412.2.1 Create an EVC Record1. On the EVC Configuration screen (Figure 12-2), type

Strona 187 - 9.1.6 OAM Remote Fault

Configuring EVC 9145E NID Software User’s ManualEVC Configuration 25511. In the Tunnel VLAN field, press the Space bar to enable or disable Tunnel VLA

Strona 188 - OAM Control

9145E NID Software User’s Manual Configuring EVCEVC Configuration25612.2.3 Modify an EVC record1. On the EVC Record List screen (Figure 12-3), type

Strona 189 - 9.2 OAM Peer Information

Configuring EVC 9145E NID Software User’s ManualEVC Configuration 25710. To modify the assigned policer profile, or allocate new policers to EVC or E

Strona 190 - 9.3 OAM Statistics

System Configuration 9145E NID Software User’s ManualIP/SNMP Agent Configuration 15Figure 3-6 Tunnel Management screen3.2.2 Auxiliary IP Configurati

Strona 191 - 9.4 OAM Event Configuration

9145E NID Software User’s Manual Configuring EVCEVC Configuration258EVC C-VLAN ID list, otherwise the request will be rejected. The ingress C-VLAN ID

Strona 192 - 9.5 OAM Event Log

Configuring EVC 9145E NID Software User’s ManualEVC Configuration 259Figure 12-8 C-VLAN to S-Tag PCP Map screen13. To specify CVID PCP translation ru

Strona 193 - OAM Event Log

9145E NID Software User’s Manual Configuring EVCEVC Configuration260Figure 12-9 P-Bit Translation Table screen14. To modify CVID to T-Tag PCP Mapping

Strona 194

Configuring EVC 9145E NID Software User’s ManualEVC Configuration 261Figure 12-10 C-VLAN to T-Tag PCP Map screen15. Press Esc to return to the EVC Re

Strona 195 - CoS Configuration

9145E NID Software User’s Manual Configuring EVCEVC Configuration262• Enter a C-VLAN ID (C-VID) and press Enter. The screen displays a page of 40 C-VI

Strona 196 - 10.2 CoS Support

Configuring EVC 9145E NID Software User’s ManualEVC Configuration 26312.2.4 Display EVC StatisticsEVC statistics can be displayed in both raw and cu

Strona 197 - 10.3 Classifier Mapping

9145E NID Software User’s Manual Configuring EVCEVC Configuration264Figure 12-13 EVC Record Statistics (Raw) screenFigure 12-14 C-VLAN Level Statis

Strona 198 - 10.3.2.1 IP Precedence Mode

Configuring EVC 9145E NID Software User’s ManualS-TPID/T-TPID Configuration 26512.3 S-TPID/T-TPID ConfigurationS-TPID and T-TPID are configured at th

Strona 199 - 10.3.2.2 DSCP Mode

9145E NID Software User’s Manual Configuring EVCS-TPID/T-TPID Configuration266

Strona 200 - 10.3.2.3 AF/EF Mode

Bandwidth Profiling 9145E NID Software User’s ManualBandwidth Profiles267Chapter 13Bandwidth Profiling This chapter describes the Ethernet Traffic eng

Strona 201 - 10.4 Queue Configuration

9145E NID Software User’s Manual System ConfigurationIP/SNMP Agent Configuration16Figure 3-7 Auxiliary IP configuration screen1. Auxiliary IP Address

Strona 202 - Queue Configuration

9145E NID Software User’s Manual Bandwidth ProfilingBandwidth Profiles268• Excess Information Parameters:• Excess Information Rate (EIR) is expressed

Strona 203

Bandwidth Profiling 9145E NID Software User’s ManualPolicers 269 Figure 13-1 Bandwidth Profiling AlgorithmWhen a packet is received of size B bytes i

Strona 204 - 10.4.4 Weight Parameters

9145E NID Software User’s Manual Bandwidth ProfilingShapers270ers can be enabled. For steps for configuring port-level policing, see the section “Set

Strona 205

Bandwidth Profiling 9145E NID Software User’s ManualShapers 271• EIR: The shaping rate for packets declared Yellow.• EBS: The output burst of Yellow p

Strona 206 - 10.6 Queue Statistics

9145E NID Software User’s Manual Bandwidth ProfilingQueue size and yellow packet thresholds27213.3.1 Shaper statisticsShaper related statistics are t

Strona 207 - Queue Statistics

Bandwidth Profiling 9145E NID Software User’s ManualConfiguring Bandwidth Profiles 27313.5 Configuring Bandwidth ProfilesUse the following steps to n

Strona 208

9145E NID Software User’s Manual Bandwidth ProfilingConfiguring Bandwidth Profiles2749. In the EBS field, type a number between 10 and 254, or 0 and

Strona 209 - Service OAM

Bandwidth Profiling 9145E NID Software User’s ManualConfiguring Bandwidth Profiles 275Figure 13-5 Create a New Bandwidth Profile screen13.5.2 Delet

Strona 210 - 11.1.1 SOAM Entities

9145E NID Software User’s Manual Bandwidth ProfilingConfiguring Bandwidth Profiles276Figure 13-6 Modify Bandwidth Profile screen Canoga Perkins Corp.

Strona 211

Bandwidth Profiling 9145E NID Software User’s ManualUser to Network Ingress Policers 27713.6 User to Network Ingress PolicersYou can view and modify

Strona 212

System Configuration 9145E NID Software User’s ManualIP/SNMP Agent Configuration 178. Aux IP Rate Limiting Enables or disables Auxiliary IP Rate Limi

Strona 213 - 11.1.4 SOAM Protocols

9145E NID Software User’s Manual Bandwidth ProfilingUser to Network Ingress Policers278Figure 13-8 Modify a Policer screen (EVC Unaware Mode)3. To ch

Strona 214

Bandwidth Profiling 9145E NID Software User’s ManualUser to Network Ingress Policers 27913.6.2 Viewing Policer Statistics1. On the Bandwidth Profile

Strona 215

9145E NID Software User’s Manual Bandwidth ProfilingUser to Network Egress Shapers28013.7 User to Network Egress ShapersThe are four shapers in the s

Strona 216 - 11.1.7 Screen Navigation

Bandwidth Profiling 9145E NID Software User’s ManualClock Rate Granularity 281Figure 13-11 Egress Shapers Configuration screen13.8 Clock Rate Granul

Strona 217 - 11.2 SOAM Configuration

9145E NID Software User’s Manual Bandwidth ProfilingColor Marking Method282

Strona 219 - SOAM Configuration

CANOGA PERKINS CORPORATION20600 Prairie StreetChatsworth, California 91311-6008 USAPhone: (818) 718-6300 FAX: (818) 718-6312Web Site: www.canog

Strona 220

9145E NID Software User’s Manual 3PrefaceAbout this ManualThis manual provides instructions on the configuration and operation of the 9145E Network In

Strona 221 - 11.3 Maintenance Domains

9145E NID Software User’s Manual System ConfigurationIP/SNMP Agent Configuration183.2.3.1 Adding or Editing a Managing Host IPTo add a Managing Host I

Strona 222 - Maintenance Domains

System Configuration 9145E NID Software User’s ManualIP/SNMP Agent Configuration 193.2.4 Trap TableOn the IP/SNMP Agent Configuration screen (Figure

Strona 223

9145E NID Software User’s Manual System ConfigurationIP/SNMP Agent Configuration20Figure 3-11 Edit Trap/Notification Type screen 5. Select the Notifi

Strona 224

System Configuration 9145E NID Software User’s ManualIP/SNMP Agent Configuration 21Figure 3-12 V1-Trap or V2c-Trap Notification Type ParameterIf you

Strona 225 - Maintenance Associations

9145E NID Software User’s Manual System ConfigurationIP/SNMP Agent Configuration22Figure 3-13 V2c-Inform Notification Type ParameterFigure 3-14 V3-T

Strona 226

System Configuration 9145E NID Software User’s ManualIP/SNMP Agent Configuration 23If you select V3-Inform (Figure 3-16):a. Type the Security Name and

Strona 227

9145E NID Software User’s Manual System ConfigurationTrap Configuration243.2.4.2 Deleting a Trap Table1. To delete a Managing Host IP address, from th

Strona 228

System Configuration 9145E NID Software User’s ManualTrap Configuration 25The System Log contains the log of all enabled Trap events. 1. To configure

Strona 229 - Maintenance Entity Groups

9145E NID Software User’s Manual System ConfigurationSecurity Configuration26Figure 3-16 Trap Configuration screen3.4 Security ConfigurationThe 9145

Strona 230

System Configuration 9145E NID Software User’s ManualSecurity Configuration 274. Minimum Punctuation Characters The minimum number of punctuation char

Strona 231

9145E NID Software User’s Manual4• Chapter 13, Bandwidth Profiling describes 9145E bandwidth profiling.New in this RevisionThe following features are

Strona 232

9145E NID Software User’s Manual System ConfigurationSecurity Configuration283.4.2 Lockout/Logout ConfigurationSelect the Lockout/Logout Configuratio

Strona 233

System Configuration 9145E NID Software User’s ManualAccount Configuration 293.5 Account ConfigurationUse the Account Configuration screen to add new

Strona 234

9145E NID Software User’s Manual System ConfigurationAccount Configuration303.5.1 Three Levels of SecurityA three-level security system on the 9145E

Strona 235 - 11.6 Maintenance End Points

System Configuration 9145E NID Software User’s ManualAccount Configuration 31Figure 3-19 Edit User Account screenUsername The name of the new accou

Strona 236 - Maintenance End Points

9145E NID Software User’s Manual System ConfigurationAccount Configuration328. Allow UI Logout Of User Gives Supervisors the ability to log users off

Strona 237

System Configuration 9145E NID Software User’s ManualSystem Information 333.6 System InformationThe System Information screen is used to add or edit

Strona 238

9145E NID Software User’s Manual System ConfigurationRADIUS Client343. Location Maximum of 25 characters.4. LATA Maximum of 3 characters.5. Customer

Strona 239

System Configuration 9145E NID Software User’s ManualRADIUS Client 3520. The values of the numbers do not matter, just the relative values of the numb

Strona 240

9145E NID Software User’s Manual System ConfigurationSNTP Client Configuration3615. RADIUS Server Priority Determines the order in which the RADIUS se

Strona 241 - 11.6.6 Linktrace Procedures

System Configuration 9145E NID Software User’s ManualSNTP Client Configuration 37Figure 3-22 SNTP Client Configuration screen3. SNTP Client Sync Int

Strona 242

9145E NID Software User’s ManualvPreface ... iiiAb

Strona 243

9145E NID Software User’s Manual System ConfigurationSYSLOG Client Configuration383.9 SYSLOG Client ConfigurationUse the SYSLOG Client Configuration

Strona 244 - 11.6.7 Loopback Procedures

System Configuration 9145E NID Software User’s ManualHardware Information 393.10 Hardware InformationThe Hardware Information screen displays informa

Strona 245

9145E NID Software User’s Manual System ConfigurationHardware Information40

Strona 246

Diagnostics 9145E NID Software User’s ManualLoopback Setup41Chapter 4Diagnostics4.0 Diagnostic FunctionsFrom the Main Menu (Figure 2-3), select (2) D

Strona 247

9145E NID Software User’s Manual DiagnosticsLatency/Jitter Test42recalculate the CRC of the looped packet when the MAC addresses are swapped, so the l

Strona 248

Diagnostics 9145E NID Software User’s ManualLatency/Jitter Test 43The leg of the trip (Local to Far End or Far End to Local) on which the P-Bit remark

Strona 249

9145E NID Software User’s Manual DiagnosticsLatency/Jitter Test44Local DSCP Rcvd The DSCP that was received at the end of the Round Trip.Figure 4-3

Strona 250

Diagnostics 9145E NID Software User’s ManualPING Generation 453. Test VLAN C/T/S The test packets will carry this VLAN Tag. The Test VLAN can only be

Strona 251

9145E NID Software User’s Manual DiagnosticsPING Generation46If the Ping to Address is in the Test Network Subnet, the Test IP will be used in the pin

Strona 252

Diagnostics 9145E NID Software User’s ManualVLAN Loopback 47 Figure 4-5 PING Generation - In Progress screen 4.4 VLAN LoopbackThe VLAN Loopback fea

Strona 253

9145E NID Software User’s Manualvi9145E Set-up ...

Strona 254 - 11.8.1 MEP Statistics

9145E NID Software User’s Manual DiagnosticsVLAN Loopback48Figure 4-6 VLAN LoopbackFigure 4-7 802.1ag Loopback Configuration Canoga Perkins Corp.

Strona 255 - 11.8.2 MIP Statistics

Diagnostics 9145E NID Software User’s ManualVLAN Loopback 491. Administration State To enable or disable the loopback responder, type 1 and press Ente

Strona 256

9145E NID Software User’s Manual DiagnosticsVLAN Loopback50Figure 4-8 VLAN Loopback Statistics screen4.4.2 L2 Ping GenerationTo set up the L2 Ping g

Strona 257 - 11.6.6.2 MIP Statistics

Diagnostics 9145E NID Software User’s ManualCable Diagnostics 51First Transaction ID Transaction identifier for the first LBM sent out in this test.LB

Strona 258 - 11.7 AIS Configuration

9145E NID Software User’s Manual DiagnosticsCable Diagnostics52• Network Port To run the diagnostics test on the Network port, type 2 and press Enter.

Strona 259 - AIS Configuration

Diagnostics 9145E NID Software User’s ManualNetwork Performance 534.6 Network Performance Performance Monitoring (PM) and Service Availability Monito

Strona 260

9145E NID Software User’s Manual DiagnosticsNetwork Performance54Note that not all firmware versions support CPM, SAM, and PLPM testing. Options for

Strona 261 - Configuring EVC

Diagnostics 9145E NID Software User’s ManualNetwork Performance 55ICMP ECHO REQUEST/REPLY packets with special fields designated in the ICMP Message B

Strona 262 - 12.1.4 Statistics

9145E NID Software User’s Manual DiagnosticsNetwork Performance56occurs when packets arrive later (or further apart) relative to previous intervals. T

Strona 263 - 12.1.5 Screen Navigation

Diagnostics 9145E NID Software User’s ManualNetwork Performance 57In the same manner, Jitter buckets can be created as shown in Figure 4-14 Figure 4

Strona 264 - EVC Functionality

9145E NID Software User’s Manual viiSNTP Client Configuration ... 34

Strona 265 - 12.2 EVC Configuration

9145E NID Software User’s Manual DiagnosticsNetwork Performance58 Figure 4-15 Profiles screen4.6.2.1 Setting up a profile.1. To view profiles, on the

Strona 266 - 12.2.1 Create an EVC Record

Diagnostics 9145E NID Software User’s ManualNetwork Performance 593. Packet TTL is the time-to-live value in hops (up to 255) for a test packet. This

Strona 267 - 12.2.2 Delete an EVC Record

9145E NID Software User’s Manual DiagnosticsNetwork Performance604.6.2.2 PM Profile Information Setup On the Profile Setup screen (Figure 4-16), type

Strona 268 - 12.2.3 Modify an EVC record

Diagnostics 9145E NID Software User’s ManualNetwork Performance 61Performance > Profile. Type A then press Enter. Select Measurement Setup then

Strona 269 - EVC Configuration

9145E NID Software User’s Manual DiagnosticsNetwork Performance62 Figure 4-18 PM Profile Setup screen (CPM State)10. CPM Duration is a time field of

Strona 270

Diagnostics 9145E NID Software User’s ManualNetwork Performance 63negative. Negative Jitter occurs when consecutive packets arrive with a shorten inte

Strona 271

9145E NID Software User’s Manual DiagnosticsNetwork Performance64For more information about CPM, see the section “Continuous Performance Monitoring” o

Strona 272

Diagnostics 9145E NID Software User’s ManualNetwork Performance 658. Unavailability (Cu) FLR Threshold (1-100%) measures the percentage of unavailabi

Strona 273

9145E NID Software User’s Manual DiagnosticsNetwork Performance66Figure 4-21 Addresses screen1. To configure test addresses, on the Network Performan

Strona 274

Diagnostics 9145E NID Software User’s ManualNetwork Performance 67the address is disabled, the address will not be tested by the PM Scheduler, even if

Strona 275

9145E NID Software User’s ManualviiiPort Filters...

Strona 276

9145E NID Software User’s Manual DiagnosticsNetwork Performance68can add additional Test Addresses, edit Addresses, or delete Test Distribution Connec

Strona 277 - S-TPID/T-TPID Configuration

Diagnostics 9145E NID Software User’s ManualNetwork Performance 698. In the Version field, type the Test Distribution protocol version (1,2, 3 or 4)

Strona 278

9145E NID Software User’s Manual DiagnosticsNetwork Performance704.6.5 Trap Configuration Use the Network Performance Traps screen to control the gen

Strona 279 - Bandwidth Profiling

Diagnostics 9145E NID Software User’s ManualNetwork Performance 71cpNPATestDistConnIPAddress – the IP of the management platform. cpNPATestDistConnSta

Strona 280 - Bandwidth Profiles

9145E NID Software User’s Manual DiagnosticsNetwork Performance724.6.7 PM Scheduler The PM Scheduler runs tests on IP Addresses in the order in which

Strona 281 - 13.2 Policers

Diagnostics 9145E NID Software User’s ManualNetwork Performance 73will be distributed evenly over 10 minutes. You can specify an End Delay Time or Af

Strona 282 - 13.3 Shapers

9145E NID Software User’s Manual DiagnosticsNetwork Performance74Table 4-2. Test Result Data FieldsThe PM Test Results screen displays a list of test

Strona 283 - Shapers

Diagnostics 9145E NID Software User’s ManualNetwork Performance 75.Figure 4-29 PM Test Results screen2. To see details, type V and press Enter. The f

Strona 284 - 13.3.1 Shaper statistics

9145E NID Software User’s Manual DiagnosticsNetwork Performance764. To view more details, on the PM Details: Latency screen, type M and press Enter to

Strona 285

Diagnostics 9145E NID Software User’s ManualNetwork Performance 774.6.9 PM Manual Test You can set up to run a test manually as part of setting up o

Strona 286

9145E NID Software User’s ManualixSoftware Reset...

Strona 287

9145E NID Software User’s Manual DiagnosticsNetwork Performance78Duration specifies the amount of time the test will run in minutes and seconds (00:01

Strona 288

Diagnostics 9145E NID Software User’s ManualNetwork Performance 791. Test packets are sent at regular intervals as specified by the Sample Period. 2.

Strona 289 - 13.6.1 Modifying a Policer

9145E NID Software User’s Manual DiagnosticsNetwork Performance80• The current state is Available and three of the four FLRs are less than the Cu (79)

Strona 290

Diagnostics 9145E NID Software User’s ManualNetwork Performance 81Figure 4-38 Round Trip Availability: Canoga NID without SAM licenceTest packets are

Strona 291

9145E NID Software User’s Manual DiagnosticsNetwork Performance82ensure that it is possible to revert to an earlier release of the firmware without lo

Strona 292 - 13.7.2 Modifying a Shaper

Diagnostics 9145E NID Software User’s ManualNetwork Performance 834.6.12 SAM Scheduler This screen allows you to set up SAM Schedules. SAM will repor

Strona 293 - 13.9 Color Marking Method

9145E NID Software User’s Manual DiagnosticsNetwork Performance844.6.13 SAM Results Log1. On the Network Performance screen, type 10 and press Enter.

Strona 294 - Color Marking Method

Diagnostics 9145E NID Software User’s ManualNetwork Performance 85Since the test packets used to perform SAM are identical to those used to perform PM

Strona 295

9145E NID Software User’s Manual DiagnosticsNetwork Performance864.6.15 Protected Link Performance MonitoringNOTE: Read this section only if you are

Strona 296 - CANOGA PERKINS CORPORATION

Diagnostics 9145E NID Software User’s ManualNetwork Performance 874.6.15.1 PLPM ConfigurationFigure 4-42 shows a model for two NIDs in a PLPM configur