Model 9135 Two-Port
and 9140 Four-Port
SNMP Managed Fast
Ethernet Switch
User Manual
Canoga Perkins
Deleted:
Deleted: and
Deleted:
Przeglądanie stron 0
1 2 3 4 5 6 ... 98 99

Podsumowanie treści

Strona 1 - Canoga Perkins

Model 9135 Two-Port and 9140 Four-Port SNMP Managed Fast Ethernet Switch User Manual Canoga Perkins Deleted: Deleted: andDeleted: ¶

Strona 2

viiiThis page intentionally left blank.

Strona 3 - NOTICE!

EdgeAccess SNMP Managed Fast Ethernet Switch Model 9135/9140 1-1 FormattedDeleted: ¶¶Deleted: Page of 871

Strona 4

1-2Chapter 1 Quick Start Installation 1.1 Typical EdgeAccess 9135 Two-Port Switch Application The application shown in Figure 1-1 represents a ca

Strona 5 - Table of Contents

EdgeAccess SNMP Managed Fast Ethernet Switch Model 9135/9140 1-3 1.2 EdgeAccess 9135/9140 Redundant Switch Application The application shown in figur

Strona 6

1-41.3 Quick Start Installation of the 9135/9140 Switch The initial setup of your EdgeAccess 9135 Two-Port or 9140 Four-Port Switch (9135/9140) inv

Strona 7 - List of Figures

EdgeAccess SNMP Managed Fast Ethernet Switch Model 9135/9140 1-5 1.4 Quick Start Interface DIP Switch Settings Although the 10/100BASE-TX UTP interf

Strona 8 - List of Tables

1-61.5 Quick Start Configuration of the 9100-300 10/100BASE-TX UTP Interface Configure the UTP interface as follows: Step 1 Insert the UTP inter

Strona 9 - Canoga Perkins EdgeAccess

EdgeAccess SNMP Managed Fast Ethernet Switch Model 9135/9140 1-7 1.6 Quick Start Configuration of the 9100-310 10/100BASE-TX UTP Interface Configure

Strona 10

1-81.7 Quick Start Configuration of the 10BASE-FL/100BASE-FX Interfaces The 9135 Two-Port and 9140 Four-Port Switch feature 10Mbps and 100Mbps fiber

Strona 11 - Model 9135/9140

EdgeAccess SNMP Managed Fast Ethernet Switch Model 9135/9140 1-9 1.8 Quick Start Interface Connection Caution: To protect the Ethernet port from an

Strona 13 - Application

1-10Step 4 Once connected, the correct operation of the local 100BASE-FX SMF interface, SMF optic cable and remote 100BASE-FX SMF interfaces can be

Strona 14 - Deleted: 1.3

EdgeAccess SNMP Managed Fast Ethernet Switch Model 9135/9140 1-11 1.10 Quick Start PC Configuration for Terminal Operation The following explanation

Strona 15 - Deleted: Page of 871

1-12Step 3 Select COM1 from the Connect using drop down menu as shown in Figure 1-10 and click OK. Note: Most computers use COM2 for the serial m

Strona 16 - 10/100BASE-TX UTP Interface

EdgeAccess SNMP Managed Fast Ethernet Switch Model 9135/9140 1-13 Step 5 At this point the HyperTerminal program will open the newly created 9135/914

Strona 17

1-14This page is intentionally left blank.

Strona 18 - FL/100BASE-FX Interfaces

EdgeAccess SNMP Managed Fast Ethernet Switch Model 9135/9140 2-1 Chapter 2 Overview 2.1 EdgeAccess 9135 Two-Port and 9140 Four-Port Fast Ethernet Sw

Strona 19 - Formatted

2-2• 9100-617: 100BASE-FX 1300nm SM fiber with ST Duplex connectors and 26dB optical budget • 9100-618: 100BASE-FX 1300nm SM fiber with SC Du

Strona 20

EdgeAccess SNMP Managed Fast Ethernet Switch Model 9135/9140 3-1 Chapter 3 Installation and Setup 3.1 Installation This section provides instructio

Strona 21 - Operation

3-23.1.3 Wall Mount Installation For a Wall Mount installation, the 9135 and 9140 Four-Port Switch feature two wall mount holes located on the botto

Strona 22

EdgeAccess SNMP Managed Fast Ethernet Switch Model 9135/9140 3-3 3.2 Setup Figure 3-4. Front View of the 9135 Two-Port Switch and 9140 Four-Port S

Strona 23 - Deleted: ¶

EdgeAccess SNMP Managed Fast Ethernet Switch Model 9135/9140 i CAUTION! This product may contain a laser diode emitter operating at a wavelength of 1

Strona 24

3-43.2.1 9100-300 10/100BASE-TX Module This module is a plug-in, which contains the 10/100BASE-TX interface, see Figure 3-5. Caution: To protect th

Strona 25 - Overview

EdgeAccess SNMP Managed Fast Ethernet Switch Model 9135/9140 3-5 3.2.2 9100-310 10/100BASE-TX Module This module is a plug-in, which contains the 10/

Strona 26 - 2.2 Main Features

3-63.2.3 100BASE-FX Single Mode Module This is a plug-in module, which contains the 100BASE-FX Single Mode interface Figure 3-6. The interface comp

Strona 27 - Installation and Setup

EdgeAccess SNMP Managed Fast Ethernet Switch Model 9135/9140 3-7 3.2.4 100BASE-FX Multimode Module This module is a plug-in which contains the 100BASE

Strona 28 - Deleted:

3-83.2.5 10BASE FL Single Mode Module This module is a plug-in which contains the 10BASE-FL Single Mode interface Figure 3-8. The interface compone

Strona 29 - 3.2 Setup

EdgeAccess SNMP Managed Fast Ethernet Switch Model 9135/9140 3-9 Deleted: ¶¶¶¶¶Deleted: Page of 871

Strona 30

3-103.2.6 10BASE-FL Multimode Module This is a plug-in module which contains the 10BASE-FL Multimode interface Figure 3-9. The interface components

Strona 31

EdgeAccess SNMP Managed Fast Ethernet Switch Model 9135/9140 3-11 3.2.7 10BASE-5 AUI Module This contains the 10BASE-5 AUI STD DTE interface. See Figu

Strona 32

3-123.2.8 Relay Contacts The alarm contacts for the 9135 Two-Port Switch and the 9140 Four-Port Switch are located next to the fan assembly on the re

Strona 33

EdgeAccess SNMP Managed Fast Ethernet Switch Model 9135/9140 3-13 3.2.9 AC/DC Power and Switch The 9135 Two-Port and 9140 Four-Port Switches can be e

Strona 34

iiNOTICE Canoga Perkins has prepared this user manual for use by customers and Canoga Perkins personnel as a guide for the proper installation, oper

Strona 35

3-14 Figure 3-14. Typical DC Power Supply Connections. The polarity of the source DC supply determines the appropriate connection to the 9135/9140

Strona 36

EdgeAccess SNMP Managed Fast Ethernet Switch Model 9135/9140 3-15 This page is intentionally left blank. Deleted: Page of 871

Strona 38 - 3.2.8 Relay Contacts

EdgeAccess SNMP Managed Fast Ethernet Switch Model 9135/9140 4-1 Chapter 4 Software Management 4.1 SNMP Management Overview - VT100 The 9135 Two-Po

Strona 39

4-24.1.4 Front Panel Diagnostics The SNMP Manager Module diagnostics for the 9135 Two-Port and 9140 Four-Port Switch are indicated on the front pane

Strona 40

EdgeAccess SNMP Managed Fast Ethernet Switch Model 9135/9140 4-3 The main functions are the following: • Self-learning Bridge (Enable / Disable Lear

Strona 41

4-44.8 BOOTP The BOOTP function supports the loading of network parameters from a BOOTP server. The following parameters are supported: • IP addres

Strona 42

EdgeAccess SNMP Managed Fast Ethernet Switch Model 9135/9140 5-1 Chapter 5 Management Setup and Operation If you have the optional 9100-M SNMP modul

Strona 43 - Software Management

5-2 Figure 5-2. Naming the HyperTerminal Connection File Step 2 The HyperTerminal program will open and prompt you to configure the serial port fo

Strona 44 - 4.3 Configuration Manager

EdgeAccess SNMP Managed Fast Ethernet Switch Model 9135/9140 5-3 Figure 5-4. COM1 Properties Screen. Step 5 At this point th

Strona 45 - 4.7 RMON Probe

EdgeAccess SNMP Managed Fast Ethernet Switch Model 9135/9140 iiiTable of Contents Chapter 1 Quick Start Installation ...

Strona 46 - 4.8 BOOTP

5-45.2 Operation of the VT100 Program If this is your initial setup and no password has been defined, the 9135/9140 will go directly to the Main Me

Strona 47 - Chapter 5

EdgeAccess SNMP Managed Fast Ethernet Switch Model 9135/9140 5-5 When the Main Menu screen appears, the user may select the appropriate screen to setu

Strona 48

5-6 Figure 5-8. IP Settings Menu. 5.2.1.1 IP Settings This screen lists all the IP settings and configurations for your management module. See Fi

Strona 49

EdgeAccess SNMP Managed Fast Ethernet Switch Model 9135/9140 5-7 • Enable BOOTP Mode: BOOTP must be enabled if the Management Module needs to obtain

Strona 50

5-8To modify the Host Table or SNMP Settings, select the desired number 1-8. Press the <Tab> key to scroll through each of the possible selecti

Strona 51 - 5.2.1 System Menu

EdgeAccess SNMP Managed Fast Ethernet Switch Model 9135/9140 5-9 After you have selected the desired field to change, the current selection will becom

Strona 52 - Page Break

5-10 Figure 5-13. Passwords Menu. Technical notes on Password Protection: When logging on, if the password string you enter matche

Strona 53

EdgeAccess SNMP Managed Fast Ethernet Switch Model 9135/9140 5-11 MENU ITEM MINIMUM ACCESS LEVEL Host Table / SNMP Settings Menu Host tabl

Strona 54

5-12 MENU ITEM MINIMUM ACCESS LEVEL Diagnostics Menu Redundancy Setting SUPERVISOR Ping Menu Ping Address USER Ping Count

Strona 55

EdgeAccess SNMP Managed Fast Ethernet Switch Model 9135/9140 5-13 Figure 5-15. Redundancy Setting Screen. 5.2.1.7 Redundancy (Back

Strona 56

iv5.2 Operation of the VT100 Program... 5-4 5.2.1 Syste

Strona 57

5-14Situation One: Port 2 Link Active / Port 1 Link Inactive / No Failures Under normal operating conditions link one shows disabled because the Par

Strona 58

EdgeAccess SNMP Managed Fast Ethernet Switch Model 9135/9140 5-15 5.2.2 Switch Configuration To set up the Switch configuration, select number 2 from

Strona 59 - Deleted: 8b

5-16 ACEBD123456A small test networkACEBD123456Spanning Tree from source (C) Figure 5-19. Graphical Depiction of a Spanning Tree Application. Wh

Strona 60 - Deleted: 8c

EdgeAccess SNMP Managed Fast Ethernet Switch Model 9135/9140 5-17 Figure 5-20. Spanning Tree Parameters. 5.2.2.2 Global Spanning Tree To enable t

Strona 61 - 5.2.2 Switch Configuration

5-18 Figure 5-21. Global Spanning Tree Parameters Menu. Port Spanning Tree Parameters can be viewed from the Port Spanning Tree sc

Strona 62 - Deleted: 0

EdgeAccess SNMP Managed Fast Ethernet Switch Model 9135/9140 5-19 Figure 5-22. Port Spanning Tree Parameters. 5.2.2.5 Spanning Tre

Strona 63

5-20 Figure 5-23. Spanning Tree Report Screen. 5.2.2.6 VLAN Configuration Note: The 9135 Two-Port Switch does not support the V

Strona 64 - Deleted: 13

EdgeAccess SNMP Managed Fast Ethernet Switch Model 9135/9140 5-21 Figure 5-25. VLAN Configuration Screen. To configure the VLAN p

Strona 65

5-225.2.3 Port Information The Port Information screen shows the individual or accumulative status of each of the 9135/9140 Ports. There is a graphi

Strona 66

EdgeAccess SNMP Managed Fast Ethernet Switch Model 9135/9140 5-23 5.2.4 Reports The Reports Menu gives the user access to a brief unit description, a

Strona 67

EdgeAccess SNMP Managed Fast Ethernet Switch Model 9135/9140 v List of Figures Figure 1-1. Typical 9135 10/100Mbps UTP/Fiber Application...

Strona 68 - 5.2.3 Port Information

5-24Number of Traps logged. 5.2.4.2 Traps Log Screen The Traps that can be reported are predefined and are not configurable as far as what traps can

Strona 69 - 5.2.4 Reports

EdgeAccess SNMP Managed Fast Ethernet Switch Model 9135/9140 5-25 5.2.5 Diagnostics The Diagnostics menu allows the user to perform Ping and Sniffer

Strona 70

5-265.2.5.2 Sniffer Settings (9140 Four-Port Switch) One of the Ports on the 9140 can be assigned as a sniffer port. When this option is selected,

Strona 71 - 5.2.5 Diagnostics

EdgeAccess SNMP Managed Fast Ethernet Switch Model 9135/9140 5-27 Figure 5-35. Restore Defaults, Restart Unit and Logout from Main Menu.

Strona 72 - 5.2.8 Logout

5-28 Step 7 One Software Revision Flash is active while the other simply holds the other version until it is invoked. This is evident because each

Strona 73

EdgeAccess SNMP Managed Fast Ethernet Switch Model 9135/9140 5-29 7. Start the FTP Client (for details, see the documentation for the client softwar

Strona 74

5-30This page is intentionally left blank.

Strona 75

EdgeAccess SNMP Managed Fast Ethernet Switch Model 9135/9140 6-1 Chapter 6 Specifications 6.1 Interfaces Number of Ports: • Two on Model 9135, plu

Strona 76

6-2100Mbps Fiber Multimode: • 100BASE-FX • ST and SC connectors • Full / Half-duplex configurable • Optical budget: minimum 11dB for 62.5/125 mi

Strona 77 - Specifications

EdgeAccess SNMP Managed Fast Ethernet Switch Model 9135/9140 6-3 6.2 Switching Characteristics Technology: ASIC based parallel Store and Forward

Strona 78

viFigure 5-23. Spanning Tree Report Screen. ... 5-20 Figure

Strona 79

6-46.3 Indicators Port: 100BASE-TX: Transmit (Tx) Link (Lnk) Collision (Col) Half / Full-duplex (Fdx) Receive (Rx) Auto (Aut)

Strona 80 - 6.4 Alarms

EdgeAccess SNMP Managed Fast Ethernet Switch Model 9135/9140 6-5 6.5 Physical / Environmental Dimensions: 17.25"W x 13.375"L x 1.75&qu

Strona 81 - 6.7 Referenced Documents

6-6 This page is intentionally left blank.

Strona 82

EdgeAccess SNMP Managed Fast Ethernet Switch Model 9135/9140 A-1 Appendix A Default Values Agent IP address unchanged Agent Netmask 255.255.

Strona 83 - Default Values

A-2 This page is intentionally left blank.

Strona 84

EdgeAccess SNMP Managed Fast Ethernet Switch Model 9135/9140 B-1Appendix B SLIP Instructions B.1 EdgeAccess Application with SNMP via SLIP The 913

Strona 85 - SLIP Instructions

B-2B.2 Configuring the 9135 or 9140 for SLIP Connect a DCE to DTE serial modem cable between the 9135 or 9140 Switch and the PC or terminal. Perfo

Strona 86

EdgeAccess SNMP Managed Fast Ethernet Switch Model 9135/9140 B-3 Verify the following settings: 1. Interface: modem 2. Init Modem At Startup: Yes

Strona 87 - Windows NT

B-4 Figure B-4a. Modem Properties. Step 3 Confirm that the modem's maximum speed is set as per the modem operator's manual (e.g. 9600 ba

Strona 88

EdgeAccess SNMP Managed Fast Ethernet Switch Model 9135/9140 B-5Step 4 Set the dialing properties of the modem as shown in Figure B-5, adjusting the

Strona 89

EdgeAccess SNMP Managed Fast Ethernet Switch Model 9135/9140 viiCanoga Perkins EdgeAccess SNMP Managed Fast Ethernet Switch Model 9135 Two-Por

Strona 90

B-6Step 6 Click the "New" tab. Figure B-7. Dial-Up Networking Screen. Under "Basic" tab, designate a name for the connection

Strona 91

EdgeAccess SNMP Managed Fast Ethernet Switch Model 9135/9140 B-7Select "Server" tab. Under "Dial-Up Server Type," highlight "

Strona 92

B-8Note: The SLIP IP address should be on a different subnet from your LAN or any other network interface using TCP/IP Stack. Verify that "For

Strona 93

EdgeAccess SNMP Managed Fast Ethernet Switch Model 9135/9140 B-9 Figure B-13. Confirm SLIP Connection. Step 9 The Ping Program in MSDOS will norm

Strona 94

B-10 In the "Connect" drop-down menu, select "Remote System." The "Connect" screen will appear as shown in figure B-1

Strona 95 - Acronyms / Abbreviations

EdgeAccess SNMP Managed Fast Ethernet Switch Model 9135/9140 C-1Appendix C Acronyms / Abbreviations AC = Alternating Current API = Application

Strona 96

C-2MIB = Management Information Base MMF = Multimode Fiber NEBS = Network Equipment Building Standards nm = nanometer (1 billionth of

Strona 97 - Limited Warranty

Appendix D Limited Warranty Limited Lifetime Warranty Effective July 1, 2005 and After, Canoga Perkins warrants that, at the time of sale, and, fo

Strona 98 - E-Mail: [email protected]

D-2Limitations Canoga Perkins may at its sole discretion modify its Limited Warranty at any time and from time to time. Other than those expressly st

Strona 99

CANOGA PERKINS CORPORATION Customer Service Department 20600 Prairie Street Chatsworth, California 91311-6008 USA Business Phone: (818) 718-6300